نویسندگان: 

Sadeghi Arian | Parhiz Alireza

اطلاعات دوره: 
  • سال: 

    2023
  • دوره: 

    10
  • شماره: 

    4
  • صفحات: 

    195-200
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    20
  • دانلود: 

    0
چکیده: 

Introduction: To determine the most appropriate method for placement of plates and screws in terms of stress in mandibular body fractures using finite element analysis. Materials and Methods: First a model of the mandible reconstructed with Mimics software. This study employed various methods, including plates positioned parallel to the inferior border of the mandible with screws perpendicular to the bone,plates parallel to the inferior border of the mandible fixed with screws oriented at a 45-degree to the fracture line,plates positioned perpendicular to the fracture line fixed with screws perpendicular to the bone,plates perpendicular to the fracture line and fixed with screws oriented at a 45-degree to the fracture line. Then the software measured the stress within the screws and plates in each condition under the maximum bite force. Results: It was observed that in cases of favorable horizontal fractures, the stress exerted on the plates and bones is greater when the plates are aligned parallel to the lower border of mandible, compared to when the plates are positioned perpendicular to the fracture line. In the study of unfavorable horizontal fractures, when the plates were fixed perpendicular to the fracture line, higher magnitudes of stress were recorded compared to the stress observed in the plates positioned parallel to the inferior border of the mandible. Conclusion: In cases of mandibular body fractures with favorable horizontal orientations, the use of fixation techniques involving plates perpendicular to the fracture line is preferred due to the reduced stress exerted on the plates. In the unfavorable horizontal fractures, the stress levels do not exhibit significant variation between different fixations. Finally, it is not advisable to utilize screws positioned at a 45-degree angle to the fracture line, as it can lead to an increase in the displacement of the plates. Keywords: Finite element analysis,Mandibular fracture,Stress and strain,Surgical plates and screws.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 20

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 1
اطلاعات دوره: 
  • سال: 

    1388
  • دوره: 

    21
  • شماره: 

    3 (مسلسل 72)
  • صفحات: 

    181-185
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    2856
  • دانلود: 

    157
چکیده: 

زمینه و هدف: در جراحیهای مدرن ارتوگناتیک و خصوصا استئوتومی ساژیتال اسپلیت، برای حفظ ثبات، فانکشن و راحتی بیماران به میزان زیادی از روشهای نوین فیکساسیون سخت استفاده می شود. کاربرد این نوع فیکساسیون علاوه بر مزایای بسیار فراوان، مشکلاتی از قبیل: نیاز به خارج کردن این ابزار در دوران بعد از جراحی را در تعدادی از بیماران به همراه دارد. هدف از این مطالعه بررسی نیاز به خارج سازی پیچ و پلاک پس از استئوتومی ساژیتال اسپلیت می باشد.روش بررسی: در یک مطالعه تحلیلی آینده نگر، 67 بیمار نیازمند عمل جراحی استئوتومی ساژیتال اسپلیت به صورت تنها و یا به صورت دو فکی در فاصله سالهای 1384-1386به بخش جراحی دهان و فک و صورت دو مرکز دانشگاهی مراجعه و پس از انجام جراحی تعداد پیچ و پلاک های خارج شده در طی یک دوره 14 ماهه پیگیری و بعد از عمل ثبت گردید. اطلاعاتی از قبیل سن، جنس، طول عمل جراحی، شرایط عمومی بیمار، جداشدگی نامطلوب در حین جراحی، سیگاری بودن بیمار و نیاز به خارج شدن دندان عقل بیمار در حین جراحی نیز ثبت و مورد ارزیابی قرار گرفت. یافته های آماری با استفاده از نرم افزار SPSS ویرایش 12 و A binary logistic regression model مورد ارزیابی قرار گرفت.یافته ها: عفونت تنها دلیل خارج کردن این نوع پلاک بود. از مجموع 134 پلاک به کار رفته در 67 بیمار، 14 پلاک در ده بیمار خارج گردید. سن به عنوان تنها عامل معنی دار برای خارج کردن پلاک مورد محاسبه قرار گرفت (P=0.001) در سایر عوامل، تفاوت معنی داری مشاهده نشد.نتیجه گیری: عفونت شایعترین دلیل خارج کردن پلاک ها و سن به عنوان تنها عامل خارج کردن پلاک های به کار رفته می باشد. تنها در تعداد کمی از بیماران، پیچ و پلاک به کار رفته نیاز به خارج کردن پیدا می نماید و نیازی به خارج کردن معمول این ابزار فیکساسیون نمی باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 2856

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 157 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1381
  • دوره: 

    26
  • شماره: 

    4-3
  • صفحات: 

    139-144
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    1053
  • دانلود: 

    0
چکیده: 

مقدمه: یکی از اهداف اصلی استئوتومی های فکی ، تامین فانکشن صحیح و ثبات قطعات استئوتومی متعاقب اعمال جراحی ارتوگناتیک می باشد و امروزه با استفاده از روشهای فیکساسیون سخت، ثبات و فانکشن بعد از عمل به حد کاملاً مطلوبی رسیده که باعث پایداری قطعات استئوتومی در محل مورد نظر می گردد. استفاده از این پیچ و پلاکهای فکی علی رغم فواید کاملا اثبات شده دارای مضرات خاص خود نیز می باشد که این مضرات به طور کامل و جامعی در اعمال جراحی ارتوگناتیک و خصوصاً استئوتومی لفورت I مشخص نگردیده است. لذا در این تحقیق بر آن شدیم تا تعداد پیچ و پلاکهای فکی برداشته شده و علل شایع خارج نمودن آنها را مورد بررسی قرار دهیم.مواد و روشها: در یک مطالعه تحلیلی آینده نگر ، 52 بیمار نیازمند استئوتومی لفورت I که در بین سالهای 1377 لغایت 1379 به بخش جراحی دهان و فک و صورت مراجعه نموده ، انتخاب و پس از انجام استئوتومی لفورت I و کاربرد فیکساسیون سخت با استفاده از پیچ و پلاکهای فکی 4  سوراخه  2 میلی متری ، بیماران برای مدتی برابر 14 ماه تحت معاینات دوره ای قرار گرفتند.یافته ها:1- از مجموع 208 پلاک بکار رفته در 52 بیمار ، در 9 بیمار ( 6 زن ، مرد ) ، 16% از پلاکها (36 عدد)  برداشته شده است 2 – جنس بیشتر پلاکهای خارج شده از جنس تایتانیوم می باشد. 3 – شایعترین علل خارج نمودن پلاکها ، بترتیب شامل : لمس شدن توسط بیمار ، سینوزیت ، درد – عفونت ، حساسیت حرارتی ، درد در لمس ، عفونت و ناشناخته می باشد. نتیجه گیری: تنها در تعداد کمی از بیماران، پیچ و پلاکهای فکی بکار رفته (16%) در محل استئوتومی ، بدلیل بروز عوارض بعد از عمل خارج گردیده است و پس از برداشتن پیچ و پلاکها در هر بیمار کلیه عوارض ناخواسته ظاهر شده، برطرف گردیده است.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 1053

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
نویسندگان: 

نشریه: 

INJURY

اطلاعات دوره: 
  • سال: 

    2019
  • دوره: 

    50
  • شماره: 

    Suppl 2
  • صفحات: 

    40-44
تعامل: 
  • استنادات: 

    1
  • بازدید: 

    71
  • دانلود: 

    0
کلیدواژه: 
چکیده: 

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 71

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1402
  • دوره: 

    14
  • شماره: 

    1
  • صفحات: 

    79-96
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    48
  • دانلود: 

    14
چکیده: 

تقویت تیرهای گلولام برای جلوگیری از افزایش حجم عنصر سازه و به جهت کاهش مصرف چوب اجتناب ناپذیر است. مقدار افزایش مقاومت این محصولات مهندسی شده به همراه استفاده محدود از سایر مصالح این مهم را فراهم می سازد. در این مطالعه، تیرهای گلولام در دو گروه چسبی و پیچی که شماری از آن ها با تسمه تقویت و یا پیش تنیده شده بودند، ساخته شدند. نمونه های گلولام این دو گروه چسبی و پیچی با تسمه و میلگرد تقویت شدند و در یکی از تیمارهای پیچی دارای پیچ و مهره میلگردی پیش تنیدگی تقریبی 5 کیلو نیوتنی ایجاد شد. پارامترهای رفتاری MOE، MOR، مقاومت و سختی نمونه ها با همدیگر مقایسه شد. همچنین تاثیر مهارهای انتهایی تیر مورد بررسی قرار گرفت. برای مقایسه ی رفتار نمونه های پیچی با چسبی، از ضریب پیشنهادی لغزش بهره جویی گردید. در بررسی ها روش آنالیز واریانس یکطرفه و مقایسه میانگین با آزمون حداقل اختلاف معنی دار انجام شد. محاسبات و تجزیه تحلیل آماری اثر معنی دار طرح های تقویتی و افزایش مقاومت انواع تیرهای چسبی را نشان می دهد. مهارهای انتهایی در تیرهای گلولام با استفاده از تسمه فولادی، نقش مؤثری را از خود نشان می دهند. مهارها حرکت نسبی لایه ها بر روی یکدیگر را کنترل نموده و در نمونه های چسبی سبب کاهش ظرفیت اما در مورد نمونه های پیچی افزایش مقاومت نهایی را باعث شدند. از آنجا که سختی از جمله پارامترهای مهم رفتاری برای بررسی خیز و خدمت پذیری آن ها در طی بهره برداری است، ضریب لغزش می تواند به عنوان پارامتر رفتاری مناسب برای مقایسه ی دو حالت چسبی و پیچی در حضور اندرکنش عوامل طراحی بکار رود. پیش تنیدگی سبب کاهش قابل توجه ضریب کشسانی به دلیل تفوق تنش های برشی ناشی از دو عامل هم زمان مهار و پیش تنیدگی بر عوامل سختی نمونه ها شده است. بطورکلی استفاده از چسب و تسمه تقویتی اثرگذاری مناسبی بر روی نمونه ها داشته و برای شرایط مصرفی متنوع پیشنهاد می شود.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 48

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 14 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
نویسندگان: 

NOBAKHT MARYAM | Hasanpour Seyed Esmail

اطلاعات دوره: 
  • سال: 

    2023
  • دوره: 

    12
  • شماره: 

    1
  • صفحات: 

    37-42
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    35
  • دانلود: 

    0
چکیده: 

Background: Previously, absorbable screw and plate systems were widely used in craniosynostosis surgery in Iran, but now, due to the establishment of economic sanctions, the importation of these tools into the country has become difficult. In this study, we compared the short-term complications of cranioplasty surgery in craniosynostosis using absorbable plate screws with absorbable sutures. Methods: In this cross-sectional study, 47 patients with a history of craniosynostosis who underwent cranioplasty at Tehran Mofid Hospital, Tehran, Iran from 2018 to 2021 were divided into two groups. For first group (31 patients) we used absorbable plate and screws, and for the second group (16 patients) absorbable sutures (PDS). All operations in both groups were performed by the identical surgical team. Patients followed up for consecutive post-operative examinations in the first and second weeks and 1, 3, and 6 months. Data were analyzed using SPSS software version 25. Results: The results did not show any short-term or medium-term complications in either group. No recurrences were observed. In Whittaker classification, 63. 8% were Class I, 29. 8% were Class II, 6. 4% were Class III, and 0% were Class IV. There was no statistically significant relationship between the type of treatment (screw and plate or absorbable suture) and higher Whitaker. There was also no statistically significant relationship between type of craniosynostosis and higher Whittaker. Conclusion: The absorbable sutures can be considered as valuable and costeffective tools in the fixation of bone fragments in craniosynostosis surgeries by surgeons.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 35

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources
اطلاعات دوره: 
  • سال: 

    2021
  • دوره: 

    7
  • شماره: 

    1
  • صفحات: 

    12-16
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    57
  • دانلود: 

    0
چکیده: 

Background: About 20% of femoral neck fracture surgeries require re-operation. The use of medial buttress plate may reduce the reoperation rate. The purpose of this study is to examine the results of using the method of augmentation of the cannulated screws with medial buttress plate for treatment of unstable femoral neck fractures. Methods: This study included patients with femoral neck fractures of Pauwels type 2 and 3 in which closed reduction was not successful. The patients underwent open anatomical reduction and implantation of three screws, and then the medial placement of the buttress plate was performed. Patients were followed up after 2 weeks, 6 weeks, 3 months, and 6 months. Union and fracture healing and operative complications were assessed using plain radiography. Results: This study included 8 patients with Pauwels type 2 and 3 femoral neck fractures. All patients were men with the mean age of 38. 0 ±,11. 3 years. Re-hospitalization 30 days after surgery, surgical site infection, deep vein thrombosis (DVT), and deep infection were not observed in any of the patients. The angle between the neck and the femur shaft dramatically increased during the 6-month follow-up (P = 0. 049). Union occurred in 6 (75%) patients after 6 months, while 2 patients were lost to follow up. Participants’,Harris Hip Score (HHS) had a significant improvement from 3 months to 6 months after surgery (P = 0. 02). Conclusion: Augmentation of cannulated screws with medial buttress plate for unstable femoral neck fractures in patients has advantages in short-term clinical follow-up.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 57

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 1
نشریه: 

TRAUMA MONTHLY

اطلاعات دوره: 
  • سال: 

    2016
  • دوره: 

    21
  • شماره: 

    2
  • صفحات: 

    0-0
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    52
  • دانلود: 

    0
چکیده: 

Background: Tibial plateau fractures can be successfully fixed utilizing 3.5mmlocking plates. However, there are some disadvantages to using these plates.Objectives: In the current prospective study, we investigated the outcome of treating different types of tibial plateau fractures with 3.5mmsimple plates which, to our knowledge, has not been evaluated in previous studies.Materials and Methods: Between 2011 and 2013, 32 patients aged 40  0.2 years underwent open reduction and internal fixation for tibial plateau fractures with 3.5mmsimple plates. The patients were followed for 16.142.1 months. At each patient’s final visit, the articular surface depression, medial proximal tibial angle, and slope angle were measured and compared with measurements taken early after the operation. The functional outcomes were measured with the WOMAC and Lysholm knee scores.Results: The mean union time was 131.2 weeks. The mean knee range of motion was 116.8°3.3°. The mean WOMACand Lysholm scores were 83.51.8 and 76.81.6, respectively. On the early postoperative and final X-rays, 87.5% and 84% of patients, respectively, had acceptable reduction. Medial proximal tibial and slope angles did not change significantly by the last visit. No patient was found to have complications related to the type of plate.Conclusions: In this case series study, the fixation of different types of tibial plateau fractures with 3.5mmsimple non-locking and non-precontoured plates was associated with acceptable clinical, functional, and radiographic outcomes. Based on the advantages and costs of these plates, the authors recommend using 3.5mmsimple plates for different types of tibial plateau fractures.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 52

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1389
  • دوره: 

    18
  • شماره: 

    2
  • صفحات: 

    78-84
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    3163
  • دانلود: 

    239
چکیده: 

زمینه و هدف: اصلاح ناحیه فرم پیشانی و کاسه چشم روش درمانی انتخابی برای بیماران مبتلا به کرانیوسینوستوز است که قسمت قدامی جمجمه و اربیت را درگیر کرده است. روش های ثابت کردن قطعات استخوانی در جراحی اصلاح ناهنجاری های جمجمه و صورت ناشی از بسته شدن زودرس درزهای جمجمه از مسایل مورد بحث در جراحی پلاستیک است. استفاده از پیچ و پلاک های قابل جذب دراین بیماران ضمن ثابت کردن کافی قطعات استخوانی، اشکالات انواع پلاک های ماندگار را ندارد. با این حال قابل لمس بودن و قابل دید بودن و زخم شدن پوست روی پلاک و تغییرات استخوانی بصورت جذب استخوان و ایجاد کپسول در اطراف آن گزارش شده است. در این مطالعه از یک ردیف  سوراخ های مش قابل جذب به جای پلاک استفاده شد و نتایج مورد بررسی قرار گرفت. مواد و روش ها: مطالعه به صورت کارآزمایی بالینی از نوع نیمه تجربی انجام شد. از اردیبهشت ماه سال 1385 تا اردیبهشت ماه 1388، 20 بیمار (14 پسر و 6 دختر) با میانگین سن 3±6 ماه (4-19 ماه) مورد عمل جراحی قرار گرفتند. دلایل انجام عمل در 8 بیمار بسته شدن زودرس سچور متوپیک، سچور کرونال یکطرفه در 5 بیمار و سچورکرونال دو طرفه در 3 بیمار و سچور ساژیتال دریک بیمار و سچورهای متعدد در 3 بیمار بود. بیماران تحت جراحی اصلاح تغییر شکل ناحیه پیشانی و حدقه چشم با برش کرونال دو طرفه قرار گرفتند، استیوتومی ناحیه فوقانی اوربیت و ادامه آن به ناحیه تمپورال بصورت زبانه در شیار (Tongue in Groove) انجام شد. برش های استخوانی همراه با شکستن استخوان بصورت دنده بشکه (Barrel Stave) برای اصلاح باریک شدن ناحیه تمپورال انجام شد. اصلاح تغییر شکل های موجود در قطعات استخوانی پیشانی بالای حدقه های چشم و قسمت فوقانی استخوان پیشانی بصورت جداگانه انجام شد. قرار دادن مجدد قطعات فوقانی کاسه چشم بصورت قرینه انجام شد و برای ثابت کردن قطعات استخوانی از پیچ و پلاک های قابل جذب ساخته شده از مش استفاده شد. یافته ها: میانگین پیگیری بیماران 6±15 ماه (36-6 ماه) بود. تمام بیماران قبل از عمل مورد ارزیابی بالینی و فتوگرافی، رادیوگرافی، سی تی اسکن سه بعدی قرار گرفتند و بعد از عمل معاینه مجدد در هفته های 1 و 2 و 3 و 6 و تا 30 ماه بعد از عمل انجام شد. در دوره های پیگیری بیماران شکستگی پلاک، عفونت، خارج شدن پلاک، قابل دید بودن، جابجایی مشاهده نشد. نتایج از نظر زیبایی براساس طبقه بندی بارتلت (Bartlett) در 90% موارد قابل قبول (Category 1 & 2 A) بود و در 10% موارد (Category 2 B) خوب بود. هیچیک از بیماران نیاز به عمل مجدد نداشتند. نتیجه گیری: استفاده از پیچ و پلاک های قابل جذب برای ثابت کردن قطعات استخوانی در بیماران مبتلا به کرانیوسینوستوز که مورد جراحی اصلاح بد شکلی ناحیه پیشانی و حدقه چشم قرار می گیرند، ثبات کافی ایجاد می کند، ولی مسایل و مشکلات وسایل فلزی دایمی را ندارد. استفاده از یک ردیف سوراخ های مش که ضخامت کمتری دارد به جای پلاک معمولی می تواند در کاهش قابل دید بودن و قابل لمس بودن و آسیب پوست موثر باشد.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 3163

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 239 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
اطلاعات دوره: 
  • سال: 

    1387
  • دوره: 

    5
  • شماره: 

    1
  • صفحات: 

    47-54
تعامل: 
  • استنادات: 

    0
  • بازدید: 

    870
  • دانلود: 

    165
چکیده: 

سابقه و هدف: امروزه به دلیل عوارض ناشی از فیکساسیون بوسیله پیچ و پلاک های تیتانیومی در جراحی (finite element analysis) BSSRO استفاده از پلیمرهای قابل جذب به عنوان جایگزین مناسب مطرح شده است. از آنجایی که تحقیقات انجام شده در این زمینه کافی نبوده لزوم انجام این مطالعه به روش اجرا محدود (FEA) مشخص می گردد.مواد و روش ها: این مطالعه به روش تجربی – آزمایشگاهی بر روی مدل بازسازی شده از فک پایین انسان در محیط نرم افزار ANsys و CATIA انجام شد. خط استئوتومی در جراحی BSSRO بر روی مدل ساخته شده اعمال گردید. سپس بارگذاری هم جهت با نیروی اکلوژن و تحت نیروهای 75 نیوتن و 135 نیوتن و 600 نیوتن صورت گرفت. الگوی توزیع تنش در فیکساسیون توسط مینی پلیت قابل جذب چهارسوراخه، مینی پلیت قابل جذب دوسوراخه و Parallel Miniplate توسط نرم افزار ANsys مورد مقایسه و آنالیز غیرخطی مکانیکی قرار گرفته.یافته ها: در بین روشهای مدل سازی شده فیکساسیون توسط پارالل مینی پلیت حداکثر استحکام اولیه را دارا می باشد. روش پلاک چهارسوراخه قابل جذب نیز می تواند ضمن تامین استحکام کافی، تروما و هزینه کمتری را هم به بیمار وارد نماید. روش پلاک دوسوراخه قابل جذب تحت نیروی 600 نیوتن نمی تواند استحکام موردنیاز را تامین نماید.نتیجه گیری: پیچ و پلاک های قابل جذب با ترکیب پلیمری: پلی گلایکولیک اسید و D و L پلی لاکتید اسید می توانند استحکام اولیه قابل قبولی را در جراحی BSSRO تامین نمایند.

شاخص‌های تعامل:   مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

بازدید 870

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesدانلود 165 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesاستناد 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resourcesمرجع 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button